Face Centered Central Composite Design Continuous Chromatography
Open access peer-reviewed chapter
Central Composite Design for Response Surface Methodology and Its Application in Pharmacy
Submitted: October 23rd, 2020 Reviewed: January 5th, 2021 Published: January 28th, 2021
DOI: 10.5772/intechopen.95835
IntechOpen Downloads
1,753
Total Chapter Downloads on intechopen.com
Abstract
The central composite design is the most commonly used fractional factorial design used in the response surface model. In this design, the center points are augmented with a group of axial points called star points. With this design, quickly first-order and second-order terms can be estimated. In this book chapter, different types of central composite design and their significance in various experimental design were clearly explained. Nevertheless, a calculation based on alpha (α) determination and axial points were clearly described. This book chapter also amalgamates recently incepted central composite design models in various experimental conditions. Finally, one case study was also discussed to understand the actual inside of the central composite design.
Keywords
- central composite design
- response surface method
- circumscribed design
- the uncoded value value of alpha (α)
- two-factor central composite design
*Address all correspondence to: sankhabhatt@gmail.com
1. Introduction
Any optimization process is achieving by going through certain phases, i.e., Screening; where identification of significant and important factor is important [1]; Improvement; where factors need to be identified which is near to optimum, Response surface design [2]; where optimum or best product has been designing by response surface method (RSM) by quantifying the relationship between one or more measured responses and vital input factor [3]. It is always been a tedious tasks to choice a suitable experimental design, which can easily explain many response variables. Such variables often end as quadratic surface model. For such kind of interpretation central composite design can be an excellent choice. In the process of Optimization and finding the best possible product from the ongoing batches, an experimental design called the central composite design (CCD) concept has emerged [4]. The CCDmodel is an integral part of response surface mythology. The biggest advantage of this type of optimization model is, it is more accurate, and no need for a three-level factorial experiment for building a second-order quadratic model [5]. After excising the CCDmodel within the experiment, a linear regression model has been used to construct the model, and coadded values have been used [6]. The CCDmodel is otherwise called A Box-Wilson Central Composite Design. In this design, the center points are eventually augmented with the group of "star points" that allows estimation of curvature [7]. If the distance from the center of the design space to a factorial point is ±1 unit for each factor, the distance from the center of the design space to a star point is ± α with ׀α׀ > 1 [8]. The precise value of α depends on certain specific properties required for the design. Since there are many factors available in the CCD model, therefore, the possibility of more than two or many star points within the model is more palpable. The star points represent lower and higher extreme values. The CCD model allows to extends 2 level factors, which have been widely used in response surface modeling and Optimization. As far as pharmaceutical research is a concerned, much scientific research has been carried out in recent times in this direction. As per Krishna Veni
However, in this book chapter, an attempt was made to highlight the basics of the CCD model and to corelate the concepts of CCD with suitable case studies, which could increase the readers' inquisitiveness.
Advertisement
2. Essential steps in responses surface methodology
-
After necessary Screening, the various factors and subsequent interactions of the experiment were identified [11].
-
The priority was given to the established various level of characteristics
-
Upon Optimization, the best suitable model has been selected [12].
-
The appropriate model, which is ideal for experimental design, can also be chosen [13].
-
To performed experimental studies, it is necessary to incept tangible factors and values which are needed to analyze systematically [14]
-
The selected model can be validated
-
There is a provision where if the data are not satisfactory, then another model of the experimental equation and experimental design is preferred. While pursuing the study, the aforementioned point c,d, and f need to be repeated until a suitable model is obtained, which is an acceptable representation of the data [15].
-
If required, a graphical representation of the surface is generated.
2.1 Models of the model used in the optimization process
The first-order model for the Optimization can be depicted as:
For quadratic or second-order model, if nonlinearity was reported, then the following equation was incorporated:
E2
The factor must be very at level three while activating to fit the second-order model [16]. It was observed that, during the dictation of center point and two-level design, the quadratic terms can be identified, but it cannot be adequately estimated [17]. In Figure 1, the condition at which the Optimization can occur was explained, i.e., Optimization can be confirmed when second order model can be optioned from statistical outcomes and which coincide with the optimum value. During the factorial design experiment, it is preferable to avoid three-level designs as chances of an increase in the number of runs would be more [16].
For CCDDesign and Box–Behnken Design, second-order models are widely used. The analyzing aspect of these two designs can be explained by the following equation:
E3
The above equation represents the quadratic model, which is near to the Optimization.
In this equation, Y = Dependent variables or Outcome variables or estimated responses, X1 = independent variables, b0 = overall mean response or intercept constant, b1 = regression model coefficients, K = number of independent variables, ϵ = error.
Put into words, a mathematical model to the observed values of the dependent variables y, that indicates:
-
Main effects for factor X1……. Xk
-
Their interactions (X1X2, X1X3…., Xk − 1, Xk)
-
Their quadratic components (X1 2,……Xk 2). No assumptions are made concerning the levels of the factors, and you can analyze any set of continuous values for the factors.
Based on the outcomes and empirical models from various experimental design, the central composite design gives us a direction to logically think and exercised multivariable analysis [18]. Three design points are prerequisite to establishing a second-order polynomial equation in CCDmodel [19]. When two levels of fractional factorial design need to be established, then 2k should have possible +1 and − 1 levels of factors. In similar patterns, 2 k needs to be calculated, which can be otherwise called star points, and α forms the center to generate quadratic terms. The center point of the CCD., the model, provides an excellent independent estimation of experimental error.
Where N is the actual number of experiments, n is a number of repetition and k is the number of different factors which were incorporated within the study. Eventually, the CCD model can be best explained by the design of an expert (Version 11.0) software. The various steps involved in central composite design (CCD) was discussed in Figure 2.
To determine the local axial point, it is necessary to identify the alpha value in the CCD model. Depending on the alpha vale design can face cantered, rotatable, orthogonal. The alpha value can be calculated using the following equation:
If α value comes equals 1, the position of axial points stands within the factorial region. This is otherwise called a face-centered design, with three levels of factors that need to be kept in the design matrix. To calculate and analyze experimental results from response surface methodology, a polynomial equation needs to be implemented to study the correlation between dependent and independent variables.
E5
Advertisement
3. Types of central composite design
The Box and Wilson design or CCD model comprising of factorial1, factorial2, and factorial3 design [20]. The star point outside the domine and the center point, representing the experimental domine, helps determine the response surface plot [21]. By estimating the precision of surface responses, the value of α can be determined; where star design is ± α. There are three types of CCD; the α can be determined according to the calculation possibilities and the required precision, which can be obtained from surface responses. The α value's positioning determines the quality of the design or estimation. The rate by design is identified by determining the position of the points [22]. The precision of the estimation influence by the number of trials at the center of the domine. The quality by design approach is necessary to estimate the coefficients' variability and responses [23]. One key aspect is rotatability or iso-variance per-rotation, which means that the prediction error is identical from all the points to the center points from the same distance [24]. Eventually, the center composite design was classified into three types:
3.1 Circumscribed design (CCC)
In central composite design, the levels of the factors eventually stand on the edge.
The CCD model (Figure 3) is always magnate with corner points, which was represented in red dots. From the center point (blue), the extract points are constrained from the sides (green dots). In this CCD model, each factor would have 5 levels. The star points are establishing new extremes for the low and high settings for all factors. These designs having circular, spherical or hyperspherical symmetry and required 5 levels for each factor. Supplementing an already existing factor or factorial design with a start point can produce the design. The Circumscribed (CCC) was found to be a rotatable design [25].
3.2 Inscribed design (CCI)
When the limit is specified for factor settings, the CCI design utilized the factor setting as star points and created a factorial design within those limits [26, 27]. In other words, CCI design is a modified version of CCC design, where CCC design has been divided by α to generate the CCI model. Eventually, CCC and CCI were found to be a rotational model (Figure 4).
3.3 Face cantered (CCF)
In this design, for each face of the factorial space, star points are the center point. Therefore. α = ±1. This variable requires 3 levels of each factor [28]. The face cantered designs (CCF) are a non-rotatable design (Figure 4).
In Figure 4, with two factors, three types of center composite design are used. From this design, one thing is clearly evidenced that; CCI explores the smallest process space, and CCC enjoys the largest process space. The CCC models looking like a sphere rotates around the factorial cube.
Advertisement
4. The parts of box and Wilson composite design
4.1 Determination of α value
Alpha (α) value can be defined as the calculated distance of each individual axial point (star point) from the center in the center composite design [29]. If Alpha (α) is less than 1, which indicates the axial point must be a cube, and if it is greater than 1, it indicates it is outside the cube. In central composite design, each factor has five levels, i.e., Extreme high or otherwise called a star point, higher point, center point, low point, and finally, extreme low star point. Figures 5 and 6 describe how to select the total number of experimental runs for the CCD model as well as how to design two factors factorial design (Table 1
Number of factors | α value related to ±1 |
---|---|
2 | ±1.414 |
3 | ±1.682 |
4 | ±2 |
5 | ±2.378 |
6 | ±2.828 |
α = (Number of factorial runs)1/4.
= (2k or 2k−r) ¼.
If K (number of factors) =2.
Alpha (α) = (22)1/4 = 22/4 = 21/2 = 1.414.
4.2 Uncoded value value of alpha (α)
Uncoded value of – α = (Coded value × L) + C.
= (−1.414 × 30) + 60 = 17.58.
Uncoded vale of + α = (Coded value× L) + C = (1.414 × 30) + 60 = 102.42 (Table 2
Level of factor | The temperature in ° C | Pressure in bar |
---|---|---|
-α (Lowest) | 17.58 | 2.93 |
−1 (Lower) | 30 | 5 |
0 (Centre point) | 60 | 10 |
+1 (High) | 90 | 15 |
+α (Highest) | 102.42 | 17.07 |
Advertisement
5. Advantages of center composite design
-
It turns out to be the extension of 2 level factorial or fractional factorial design [21]
-
To estimate nonlinearity of responses in the given data set
-
Helps to estimate curvature in obtained continuous responses
-
Maximum information in a minimum experimental trial
-
Reduction in the number of trials required to estimate the squared terms in the second-order model
-
They have been widely used in response to surface modeling and Optimization (Tables 3 and 4)
No. | Factor A | Factor B | |
---|---|---|---|
1. | | −1 | -1 |
2. | 1 | -1 | |
3. | -1 | 1 | |
4 | 1 | 1 | |
5. | | −1.44 | 0 |
6. | 1.414 | 0 | |
7. | 0 | −1.414 | |
8. | 0 | 1.414 | |
9. | | 0 | 0 |
No. | Factor A | Factor B | Factor C | |
---|---|---|---|---|
| | −1 | −1 | −1 |
| 1 | −1 | −1 | |
| −1 | 1 | −1 | |
| 1 | 1 | −1 | |
| −1 | −1 | 1 | |
| 1 | −1 | 1 | |
| −1 | 1 | 1 | |
| 1 | 1 | 1 | |
| | −1.682 | 0 | 0 |
| 1.682 | 0 | 0 | |
| 0 | −1.682 | 0 | |
| 0 | 1.682 | 0 | |
| 0 | 0 | −1.682 | |
| 0 | 0 | 1.682 | |
| | 0 | 0 | 0 |
Advertisement
6. Limitation of central composite design
-
It was observed that the star points are outside the hypercube, so the number of levels that have to be adjusted for every factor is five instead of three, and sometimes it is not easy to achieve the adjusted values of factors [32].
-
Depending upon the Design, the squared terms in the model will not be orthogonal to each other.
-
Inability to estimate individual interaction terms, i.e., linear by quadratic or quadratic by quadratic.
Same examples of CCDoptimization in recent experimental conditions are mentioned in Table 5.
Title of the research | Author and Year | Model utilized | Variables taken | Findings | References |
---|---|---|---|---|---|
Development and optimization of baicalin-loaded solid lipid nanoparticles prepared by coacervation method using central composite design | Jifu Hao .et.a.l (2012) | central composite design | A two-factor five-level central composite design (CCD) was introduced. | The composition of optimal formulation was determined as 0.69% (w/v) lipid and 26.64% (w/w) drug/lipid ratio. The results showed that the optimal formulation of baicalin-loaded SLN had entrapment efficiency (EE) of 88.29%, particle size of 347.3 nm and polydispersity index (PDI) of 0.169. | |
Formulation, Development and Optimization of Propranolol Mucoadhesive Bilayer Tablets by Using Central Composite Design and its In Vitro Studies | Asif MASSUD | Angle of repose, compressibility index, bulk and tapped densities, Hausner's ratio for powders and granules were performed. | Mucoadhesive tablets with adequate mucoadhesion by adopting a new oral drug delivery concept Power was successfully developed to prevent liver degradation and propranololol enhancement Bioavailability Availability | [34] | |
Statistical Analysis of the Tensile Strength of Coal Fly Ash Concrete with Fibers Using Central Composite Design | Barbuta Marinela, et al. (2015) | CCD, Response Surface Method (RSM.) | Length, percentage, The total number of tests were statistically established taking into account the number of independent variables, the type of analyze that was done and the type of experimental plan that was chosen | DOE is a structured, organized method that is used to determine the relationship between the different factors affecting a process and the output of that process. Analysis of variance (ANOVA) is a common method used to compare the relative strength of two related models | [35] |
Response surface modeling of lead (׀׀) removal by graphene oxide-Fe3O4 nanocomposite using a central composite design | Khazaei Mohammad et al. (2016) | CCD, RSM (Response Surface Methodology) | 4 independent variables: initial pH of Solution, nanocomposite dosage, contact time, initial lead ion concentration | Quadratic and reduced models were examined to correlate the variables with the removal efficiency of Magnetic Graphene Oxide. According to ANOVA, influential factors were pH and contact time. | [36] |
Optimization of ferulic acid production from banana stem waste using central composite design | Sharif Nurul Shareena Aqmar Mohd (2017) | CCD, RSM (Response Surface Methodology) | Ratio of water to Banana stem waste (BSW), incubation time (hrs) | The RSM-CCD method optimize the hydrolysis conditions for maximum ferulic acid production. Hence, B.S.W. is proven useful and highly feasible for producing good quality natural products. | [37] |
Central Composite Design Optimization of Zinc Removal from Contaminated Soil, Using Citric Acid as Biodegradable Chelant | Asadzadeh Farrokh et al. (2018) | CCD, RSM. | Citric acid concentration, pH, washing time | RSM based CCD is a promising tool for modeling and optimizing Zn removal from the contaminated soil using citric acid. It was found that pH and citric acid conc. Are the significant parameters in Zn removal process. | [38] |
Removal of reactive red-198 dye using chitosan as an adsorbent: Optimization by Central composite design coupled with response surface methodology | Haffad Hassan et al. (2019) | C.C.D., Langmuir isotherm model, pseudo-second-order equation | pH,Concentration, temperature | Chitosan material based shrimp cells have countless opportunities in use of waste water treatment. The major effect is played by pH | [39] |
Mixture optimization of high-strength blended concrete using central composite design | Hassan Wan Nur Firdaus Wan et al. (2020) | CCD, RSM. | Micro and Nano Palm Oil Fuel Ash (POFA.) | Mixture optimization of high-strength blended concrete using central composite Design, Run 1, containing 10% micro POFA and 2% nano POFA, showed the highest flexural strength | [40] |
Advertisement
7. Case study-1
As per S. Bhattacharya., (2020) studies [41] varius independent variables viz., entrapment efficacy percentage, zeta potential, particle size, percentage of calmative drug release of a polymeric nanoparticle formulation was evaluated and optimized using central composite design (CCD); which was interpreted by Design Expert (Stat-Ease; version 11.0) software. Upon considering the alpha point at 1.68179, in this 21 baches experimental design, 4 factors, and 2 levels were considered (Table 6). Based on the optimization surface plot batch with desired particle size, zeta potential, cumulative drug release (%) entrapment efficacy (%) were selected for further characterization studies. Table 7 indicating critical quality attributes and necessary process attributes that affect the outcomes of the nanoparticles. By using polynomial equations and a 3-dimensional surface plot, the effects of critical process parameters on essential attributes of quality were examined Figure 7.
S. No | Factors | Low Value | High Value |
---|---|---|---|
1 | Homogenization speed (rpm) | 10000 | 15000 |
2 | | 10 | 15 |
3 | Surfactant Concentration (%) | 1 | 1.25 |
4 | Polymer concentration (mg/mL) | 3 | 6 |
S. No | Critical Quality Attributes | Desired constrained |
---|---|---|
1 | Particle Size (nm) | Finest |
2 | Zeta Potential (mV) | Finest |
3 | Cumulative drug release (%) | Moderately high |
4 | Entrapment efficacy (%) | Supreme |
From this CCDmodel, the following polynomial equations can be derived:
E6
E7
E8
E9
By considering A as homogenization speed, B as homogenization time, C as surfacetant concentration (%) and D as polymeric concentration; respectively, the polynomial Eqs. 6, 7, 8, & 9 can be interpreted. From these polynomial equations, critical process parameters of qualifiable effects on essential attributes can be determined. It can easily predict from the polynomial Eq. 6, that particle size of the polymeric nanoparticles can be increased, when homogenization time & speed and surfactant concentration decrease. The elevated negative co-efficient in homogenization speed of polynomial Eq. 6, indicates it has a significant influence on particle size. Higher shearing stress during elevated homogenization time & speed could lead to mass transfer between the particles, ultimately resulting in nucleation and smaller particle size. From Eq. 7, it can be predict that homogenization time & surfactant concentration has antagonistic effects on zeta potential and homogenization speed has an agonistic effect on zeta potential. In a similar fashion equation 8, shows homogenization speed & surfactant concentration has an agonistic effect on cumulative drug release (%) at 80th hours. From Eq. 9 it was clear that entrapment efficacy (%) increases with increases of homogenization speed, homogenization time & surfactant concentration.
Advertisement
8. Case study 2
As per Jaleh Varshosaz
Advertisement
9. Conclusion
This book chapter's main agenda was to enlighten the present approaches and recent optimization research activities based on the CCD model, as specially for pharmaceutical product development. The CCDmodel is useful for modeling and analyzing programs in which the response of interest influences several variables. The CCDmodel can be considered as a robust statistical tool for process optimization. The best part of CCDis, as compared to Plackett–Burman design, a limited number of experiments are required with less computational experience. The biggest challenge of the CCDmodel is finding the critical factor. Central composite designs are beneficial in sequential experiments because you can often build on previous factorial experiments by adding axial and center points.
Advertisement
Acknowledgments
The author is like to acknowledge the help and motivation of Dr. R.S. Gaud, Director, SVKM's NMIMS. Deemed-to-be University, Shirpur Campus, for providing excellent research facilities and profound inspiration while drafting this book chapter. The author is also like to acknowledge his own original research publication entitled "Fabrication and characterization of chitosan-based polymeric nanoparticles of Imatinib for colorectal cancer targeting application"; for taking inputs from that article while drafting this book chapter.
Conflict of interest
The author declares that the author has no competing interests.
References
- 1.
Cooper, R.G., S.J. Edgett, and E.J.J.R.-T.M. Kleinschmidt, Optimizing the stage-gate process: what best-practice companies do—I. 2002.45 (5): p. 21–27. - 2.
Del Castillo, E., Process optimization: a statistical approach . Vol. 105. 2007: Springer Science & Business Media. - 3.
Kilickap, E., M. Huseyinoglu, and A.J.T.I.J.o.A.M.T. Yardimeden, Optimization of drilling parameters on surface roughness in drilling of AISI 1045 using response surface methodology and genetic algorithm. 2011.52 (1–4): p. 79–88. - 4.
Beg, S., et al., Application of design of experiments (DoE) in pharmaceutical product and process optimization , inPharmaceutical quality by design . 2019, Elsevier. p. 43–64. - 5.
Granato, D., et al., The use and importance of design of experiments (DOE) in process modelling in food science and technology. 2014.1 : p. 1–18. - 6.
Ellis, D.I., et al., Rapid identification of closely related muscle foods by vibrational spectroscopy and machine learning. 2005.130 (12): p. 1648–1654. - 7.
Bevilacqua, A., et al., Design of experiments: a powerful tool in food microbiology. 2010: p. 1419–1429. - 8.
Coman, G. and G.J.A.o.m. Bahrim, Optimization of xylanase production by Streptomyces sp. P12–137 using response surface methodology and central composite design. 2011.61 (4): p. 773–779. - 9.
Veni, D.K., N.V.J.I.J.o.P.M. Gupta, and P. Biomaterials, Development and evaluation of Eudragit coated environmental sensitive solid lipid nanoparticles using central composite design module for enhancement of oral bioavailability of linagliptin. 2020.69 (7): p. 407–418. - 10.
Ye, Q., et al., Development and evaluation of puerarin-loaded controlled release nanostructured lipid carries by central composite design. 2020: p. 1–37. - 11.
Imandi, S.B., et al., Application of statistical experimental designs for the optimization of medium constituents for the production of citric acid from pineapple waste. 2008.99 (10): p. 4445–4450. - 12.
Candioti, L.V., et al., Experimental design and multiple response optimization. Using the desirability function in analytical methods development. 2014.124 : p. 123–138. - 13.
Zolgharnein, J., M. Bagtash, and N.J.J.o.E.C.E. Asanjarani, Hybrid central composite design approach for simultaneous optimization of removal of alizarin red S and indigo carmine dyes using cetyltrimethylammonium bromide-modified TiO2 nanoparticles. 2014.2 (2): p. 988–1000. - 14.
Schmid, R.F., et al., The effects of technology use in postsecondary education: A meta-analysis of classroom applications. 2014.72 : p. 271–291. - 15.
Gefen, D., D. Straub, and M.-C.J.C.o.t.a.f.i.s. Boudreau, Structural equation modeling and regression: Guidelines for research practice. 2000.4 (1): p. 7. - 16.
Jones, B. and C.J.J.J.o.Q.T. Nachtsheim, A class of three-level designs for definitive screening in the presence of second-order effects. 2011.43 (1): p. 1–15. - 17.
Bezerra, M.A., et al., Response surface methodology (RSM) as a tool for optimization in analytical chemistry. 2008.76 (5): p. 965–977. - 18.
Esbensen, K.H., et al., Multivariate data analysis: in practice: an introduction to multivariate data analysis and experimental design . 2002: Multivariate Data Analysis. - 19.
Chu, P.C. and C.J.J.o.C.P. Fan, A three-point combined compact difference scheme. 1998.140 (2): p. 370–399. - 20.
Yolmeh, M., S.M.J.F. Jafari, and B. Technology, Applications of response surface methodology in the food industry processes. 2017.10 (3): p. 413–433. - 21.
Tarley, C.R.T., et al., Chemometric tools in electroanalytical chemistry: methods for optimization based on factorial design and response surface methodology. 2009.92 (1): p. 58–67. - 22.
Wang, G.G.J.J.M.D., Adaptive response surface method using inherited latin hypercube design points. 2003.125 (2): p. 210–220. - 23.
Xu, X., M.A. Khan, and D.J.J.I.j.o.p. Burgess, A quality by design (QbD) case study on liposomes containing hydrophilic API: II. Screening of critical variables, and establishment of design space at laboratory scale. 2012.423 (2): p. 543–553. - 24.
Pradhan, M., et al., Quality by design and formulation optimization using statistical tools for safe and efficient bioactive loading , inAdvances and Avenues in the Development of Novel Carriers for Bioactives and Biological Agents . 2020, Elsevier. p. 555–594. - 25.
Singh, B., R. Kumar, and N.J.C.R.i.T.D.C.S. Ahuja, Optimizing drug delivery systems using systematic "design of experiments." Part I: fundamental aspects. 2005.22 (1). - 26.
Leiviskä, K.J.U.o.O.C.E.L., Introduction to experiment design. 2013. - 27.
Cavazzuti, M., Design of experiments , inOptimization methods . 2013, Springer. p. 13–42. - 28.
Hasanien, H.M., A.S. Abd-Rabou, and S.M.J.I.T.o.E.C. Sakr, Design optimization of transverse flux linear motor for weight reduction and performance improvement using response surface methodology and genetic algorithms. 2010.25 (3): p. 598–605. - 29.
Asghar, A., A.A. Abdul Raman, and W.M.A.W.J.T.S.W.J. Daud, A comparison of central composite design and Taguchi method for optimizing Fenton process. 2014.2014 . - 30.
Ait-Amir, B., P. Pougnet, and A. El Hami, 6 - Meta-Model Development, in Embedded Mechatronic Systems 2, A. El Hami and P. Pougnet, Editors. 2015, Elsevier. p. 151-179. - 31.
Rajmohan T, Palanikumar K. Application of the central composite design in optimization of machining parameters in drilling hybrid metal matrix composites. Measurement. 2013 May 1;46(4):1470-81. - 32.
Ferreira, S.L.C., et al., Statistical designs and response surface techniques for the optimization of chromatographic systems. 2007.1158 (1–2): p. 2–14. - 33.
Hao, J., et al., Development and optimization of baicalin-loaded solid lipid nanoparticles prepared by coacervation method using central composite design. 2012.47 (2): p. 497–505. - 34.
Massud, A., et al., Formulation, development and optimization of propranolol mucoadhesive bilayer tablets by using central composite design and its in-vitro studies. 2015.34 (8): p. 1637–44. - 35.
Barbuta, M., et al., Statistical analysis of the tensile strength of coal fly ash concrete with fibers using central composite design. 2015.2015 . - 36.
Khazaei, M., et al., Response surface modeling of lead (׀׀) removal by graphene oxide-Fe 3 O 4 nanocomposite using central composite design. 2016.14 (1): p. 2. - 37.
Mohd Sharif, N.S.A., et al., Optimization of ferulic acid production from banana stem waste using central composite design. 2017.36 (4): p. 1217–1223. - 38.
Asadzadeh, F., et al., Central composite design optimization of zinc removal from contaminated soil, using citric acid as biodegradable chelant. 2018.8 (1): p. 1–8. - 39.
Haffad, H., et al., Removal of reactive red-198 dye using chitosan as an adsorbent: optimization by Central composite design coupled with response surface methodology. 2019: p. 1–13. - 40.
Hassan, W.N.F.W., et al., Mixture optimization of high-strength blended concrete using central composite design. 2020.243 : p. 118251. - 41.
Bhattacharya, Sankha. "Fabrication of poly (sarcosine), poly (ethylene glycol), and poly (lactic-co-glycolic acid) polymeric nanoparticles for cancer drug delivery." Journal of Drug Delivery Science and Technology (2020): 102194. - 42.
Varshosaz, J., et al., Development and optimization of solid lipid nanoparticles of amikacin by central composite design. 2010.20 (2): p. 97–104.
Submitted: October 23rd, 2020 Reviewed: January 5th, 2021 Published: January 28th, 2021
© 2021 The Author(s). Licensee IntechOpen. This chapter is distributed under the terms of the Creative Commons Attribution 3.0 License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Source: https://www.intechopen.com/chapters/74955
0 Response to "Face Centered Central Composite Design Continuous Chromatography"
Post a Comment